“iE0” – code: flow control position (spray arm level)
• The alarm is stored and displayed only in service mode; there is a new control for
each new phase.
• The alarm is signalled if the desired position of the flow controller is not reached after
120 sec; the
• heating element is deactivated.
• If the signal from the flow controller does not change after 15 sec, the software
suspends the positioning for 2 sec and resumes after another max 120 sec.
“i11” code: during dynamic filling
• Acoustic signal and visual alarm, depending on the appliance customization; the
program can be restarted.
• The water level defined is not reached within the time limit set.
• The time limit set starts when the fill solenoid valve is opened.
• The time limit set is reset when the fill solenoid valve is closed.
• The water will first be drained before an error is displayed to the user.
• Time limit set: Normal 120 sec; Test cycle = 60 sec (times could differ as they are
defined in the washing cycle specifications)
62 нет есть 61
“i61” – code: heating over temperature
• if water temperature is detected higher than 78°C, cycle is stopped.
(rem.: origin of this alarm is problem on visi plastic doors)