Сортировка вопросов
Ответы 5
21 января 2016
решил проблему 7-го пина, все прошилось, вопрос прикрыт до инсталляции плату в СМА. всем спасибо.
20 января 2016
сам нашел
даташит: This input signal is useful for protecting the entire contents of the memory from inadvertent
write operations. Write operations are disabled to the entire memory array when Write
Control (WC) is driven High. When unconnected, the signal is internally read as VIL, and
Write operations are allowed.
When Write Control (WC) is driven High, Device Select and Address bytes are
acknowledged, Data bytes are not acknowledged.
https://sw19.ru/forum/490
Ответ простой- 24С64WP вывод 7 (wc) единица - только читаем, ноль пишем.На ch341T он висит..
даташит: This input signal is useful for protecting the entire contents of the memory from inadvertent
write operations. Write operations are disabled to the entire memory array when Write
Control (WC) is driven High. When unconnected, the signal is internally read as VIL, and
Write operations are allowed.
When Write Control (WC) is driven High, Device Select and Address bytes are
acknowledged, Data bytes are not acknowledged.
https://sw19.ru/forum/490
Ответ простой- 24С64WP вывод 7 (wc) единица - только читаем, ноль пишем.На ch341T он висит..
20 января 2016
alexragulin, Будьте добры изложите более подробно про перемычку, или дайте ссылку на тему.
20 января 2016
в общем у меня есть два модуля, оригинальный с электрическими повреждениями (380В попало) и новый и справный, прошивки в них не сходятся, я не могу перезалить прошивку из старой платы в новую, не могу понять в чем дело.
20 января 2016
с моим файлом не сходится.
Еще не могу перезалить прошивку с помощью прищепки. ППЗУ не очищается и не заливается новая прошивка.
Еще не могу перезалить прошивку с помощью прищепки. ППЗУ не очищается и не заливается новая прошивка.